II-1000 Series Infant Incubator

Standrad configuration: High performance microcomputer control; touch film key operation; constant temperature cover with inclined plane; two display screens for set temp, box inner temp; >37��/span> set-up; set-off memory; warning for: set-off, fan, sensor, over box inner temp. & temp. deviation; warning silencing function, self-test; wall cupboard and shelf and RS-232 or 485 connector.

 

II-1000YC

Standard configuration + Infant bed adjusted with stepless.

 

 

II-1000SGL

Standard configuration + Two phototherapy竊�/span>blue light竊�/span>unit, LED display timer, display treatment time and total time.

 

Specifications:

Power Supply: AC 110/220V±10%, 50/60Hz±2%
Heating Power: ≤400VA
Convenience Outlets: AC 110/220V±10%,
50/60Hz±2%
With respect to IEC601-1, this equipment is Class I, Type B

Continuous operation with short time loading竊�/span>VHA竊�/span>

 

Alarms:
1. Power Alarm
Power failure: Activates if primary power to the incubator fails or the power code is accidentally disconnected from the wall receptacle.

2. Fan Alarm
Fan failure: Activate if fan electromotor failure or fan power failure, or fan rotate speed below 1,000 turn/min because of outside force.

3. Sensor Alarm
Air sensor failed: Air sensor malfunction.
Sensor failure: Air sensor not connected to the incubator.

4. Deviation Alarm
High air temperature: Activated if displayed air temperature is 1.5��/span> above set point.
• Low air temperature: Activated if displayed air temperature is 2.5��/span> below set point.

5. Over Temperature Alarm
• Over air temperature: Activated if incubator temperature arriv
ed 38��/span> for set temps <37��/span> in Air Mode; arrived 40��/span> for set temps >37��/span> in Air Mode.

Silence function of “
��/span>/Silence Complex Key”
The “
��/span>/Silence Complex Key” can make following alarm silenced for 15 minutes.
• Deviation Alarm
• Sensor Alarm
• Fan
Alarm

 

 

 

 